Poyraz series heat pump
R290 heat pump for regions where winters stay around −7 °C. 12, 14 and 16 kW models, leaving water up to 55 °C.

Indoor unit with tank that heats with water and cools through air conditioner indoor units; in summer it uses the heat from cooling to make hot water with no extra energy.
HİDREM was developed for buildings without fan coil pipework. It uses the same floor-standing casing with tank as HİDRA; the difference is that it also carries a direct-expansion cooling circuit. In winter it supplies underfloor heating or radiators through the water circuit; in summer it sends the refrigerant directly to wall-mounted air conditioner indoor units.
Cooling with water requires fan coil pipework and well-insulated pipes; most existing buildings do not have this infrastructure. Because air conditioners serve as the indoor units, no fan coil pipework is needed. Since the refrigerant goes directly to the indoor unit, there is no water circuit in between; heat transfer losses are reduced and cooling is more efficient.
An ordinary air conditioner rejects the heat it draws from the room to the outside while it cools. HİDREM transfers this heat to the water in the tank: while cooling is running, the water heats up too, and no extra energy is spent on domestic hot water throughout the summer.
Depending on capacity, the tank holds between 80 and 140 litres and, depending on the configuration, works as a buffer tank, a storage tank or a hot water cylinder. The inner surface can be stainless steel or black enamel. Solar collectors on the roof join the system through the second Grundfos pump in the unit.
As with HİDRA, the unit sits on a mounting frame; because the frame dimensions are fixed, the connections can be prepared in advance and installation is quicker. Since the pipework can be connected from the right, the left or the top, it also fits into tight plant spaces. Fittings that are normally bought separately on site come ready in the casing, which makes installation and any later work on the unit easier.
The 8-inch touch panel is integrated with the control board. Where the infrastructure allows, the unit is commissioned and managed remotely; in the event of a fault, a notification arrives by e-mail. Energy consumption is shown on the panel daily, monthly and yearly.
HİDREM is built in five classes between 8 and 16 kW and pairs with the Poyraz, Vaha or Boran outdoor units.
Scroll the table sideways
| Model | HDRM8 | HDRM10 | HDRM12 | HDRM14 | HDRM16 |
|---|---|---|---|---|---|
| Mounting type | Floor-standing, with tank | Floor-standing, with tank | Floor-standing, with tank | Floor-standing, with tank | Floor-standing, with tank |
| Heating capacity, min – max (kW) | 1.3 – 8 | 1.72 – 10 | 2.3 – 12 | 2.5 – 14 | 2.7 – 16 |
| Cooling capacity, min – max (BTU/h) | 3,414 – 20,125 | 5,462 – 27,390 | 7,852 – 32,620 | 9,559 – 37,769 | 10,430 – 41,172 |
| Outdoor air operating range (°C) | −25 … +40 | −25 … +40 | −25 … +40 | −25 … +40 | −25 … +40 |
| Heating water temperature (°C) | +30 … +55 | +30 … +55 | +30 … +55 | +30 … +55 | +30 … +55 |
| Cooling circuit | Direct expansion (air conditioner indoor unit) | Direct expansion (air conditioner indoor unit) | Direct expansion (air conditioner indoor unit) | Direct expansion (air conditioner indoor unit) | Direct expansion (air conditioner indoor unit) |
| Cooling operating temperature (°C) | −5 … 0 | −5 … 0 | −5 … 0 | −5 … 0 | −5 … 0 |
| Circulation pump | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h |
| Solar circuit pump | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h |
| Built-in tank volume (L) | 80 | 100 | 125 | 140 | 140 |
| Max. power input (W) | 30 – 130 | 30 – 130 | 30 – 130 | 30 – 130 | 30 – 130 |
| Power supply | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz |
| Sound pressure at 1 m (dB(A)) | 22 | 22 | 22 | 34 | 34 |
| Refrigerant + air conditioner connection (in) | 3/8" – 5/8" + 3/8" – 5/8" | 3/8" – 5/8" + 3/8" – 5/8" | 3/8" – 5/8" + 3/8" – 5/8" | 3/8" – 3/4" + 3/8" – 3/4" | 3/8" – 3/4" + 3/8" – 3/4" |
| Hot water connection (mm) | Ø15 | Ø15 | Ø15 | Ø15 | Ø15 |
| Heating connection (mm) | Ø25 | Ø25 | Ø25 | Ø25 | Ø25 |
| Unit dimensions W × D × H (mm) | 500 × 1520 × 500 | 500 × 1650 × 500 | 500 × 1650 × 500 | 500 × 1750 × 500 | 500 × 1750 × 500 |
| Shipping dimensions W × D × H (mm) | 550 × 1620 × 550 | 550 × 1750 × 550 | 550 × 1750 × 550 | 550 × 1850 × 550 | 550 × 1850 × 550 |
| Weight (kg) | 123 | 127 | 134 | 139 | 140 |
Tell us the model and the project; we will help you choose the right capacity.
After installation, this product is serviced and maintained by our group company Aktek Elektromekanik. Service by Aktek Elektromekanik

R290 heat pump for regions where winters stay around −7 °C. 12, 14 and 16 kW models, leaving water up to 55 °C.

R290 heat pump with vapour injection for long, harsh winters: 65 °C leaving water at −25 °C outdoor air, 12–16 kW.

R32 heat pump for coastal climates, with mild winters and long, hot summers. 12–16 kW heating at +2 °C outdoor air, strong cooling.

R290 + R134a cascade heat pump for Eastern Anatolia and high altitude. 75 °C water at −30 °C outdoor air, 12–16 kW, buffer tank inside.