Poyraz series heat pump
R290 heat pump for regions where winters stay around −7 °C. 12, 14 and 16 kW models, leaving water up to 55 °C.

Wall-hung heat pump indoor unit for buildings with little plant space. Heating and cooling, 8–16 kW; external cylinder and direct-expansion cooling options.
HİD / HİT gathers the hydraulic side of the heat pump in a wall-hung casing the size of a combi boiler. It transfers the heating and cooling energy produced by the outdoor unit to the circuits in the building, with no need to set aside a separate boiler room or a large plant room. It can be mounted on the utility balcony of an apartment or on a corridor wall in a small office or shop. The casing of the 8–12 kW models measures 510 × 1000 × 350 mm.
The expansion vessel, the circulation pump, the main and auxiliary heat exchangers and the main hydraulic block are inside the unit; no separate pump group is installed on site. The circulation pump is made by Grundfos. Because the hydraulic lines are made of copper and brass, there is little wear from corrosion and scale. The sound level is between 18 and 23 dB(A) at 1 metre.
There is no tank in the casing; domestic hot water is prepared in an external cylinder. Depending on the model, the cylinder that can be connected holds 80, 100, 125 or 140 litres. In homes with solar collectors, the collector line is connected to the system through the second Grundfos pump in the unit.
Cooling is done with water: the unit supplies a fan coil or underfloor cooling circuit. If direct-expansion cooling is wanted in a particular room, a wall-mounted air conditioner indoor unit can be added to the unit.
With the additional setting switches on the control board, the unit is set up for one of three scenarios: heating only; heating and cooling; or heating, cooling and hot water. The same switches adapt it to different system layouts, such as a single or twin coil cylinder or a circuit with a heat exchanger; which one to choose is decided by the system design.
HİD / HİT is built in five capacity classes (8, 10, 12, 14, 16 kW) and pairs with the Poyraz, Vaha and Boran outdoor units. The class is determined by the power of the outdoor unit to be connected and the building's heat loss.
Scroll the table sideways
| Model | HD8 | HD10 | HD12 | HD14 | HD16 |
|---|---|---|---|---|---|
| Mounting type | Wall-hung | Wall-hung | Wall-hung | Wall-hung | Wall-hung |
| Heating capacity, min – max (kW) | 1.3 – 8 | 1.72 – 10 | 2.3 – 12 | 2.5 – 14 | 2.7 – 16 |
| Cooling capacity, min – max (BTU/h) | 3,414 – 20,125 | 5,462 – 27,390 | 7,852 – 32,620 | 9,559 – 37,769 | 10,430 – 41,172 |
| Outdoor air operating range (°C) | −25 … +40 | −25 … +40 | −25 … +40 | −25 … +40 | −25 … +40 |
| Heating water temperature (°C) | +30 … +55 | +30 … +55 | +30 … +55 | +30 … +55 | +30 … +55 |
| Chilled water temperature (°C) | +2 … +7 | +2 … +7 | +2 … +7 | +2 … +7 | +2 … +7 |
| Circulation pump | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h |
| Solar circuit pump | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h | Grundfos, 1,700 L/h |
| Connectable cylinder volume (L) | 80 | 100 | 125 | 140 | 140 |
| Max. power input (W) | 30 – 130 | 30 – 130 | 30 – 130 | 30 – 130 | 30 – 130 |
| Power supply | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz | 220–240 V / 1 phase / 50–60 Hz |
| Sound pressure at 1 m (dB(A)) | 18 | 18 | 18 | 23 | 23 |
| Refrigerant connection (in) | 3/8" – 5/8" | 3/8" – 5/8" | 3/8" – 5/8" | 3/8" – 3/4" | 3/8" – 3/4" |
| Hot water connection (mm) | Ø15 | Ø15 | Ø15 | Ø15 | Ø15 |
| Heating / cooling connection (mm) | Ø25 | Ø25 | Ø25 | Ø25 | Ø25 |
| Unit dimensions W × D × H (mm) | 510 × 1000 × 350 | 510 × 1000 × 350 | 510 × 1000 × 350 | 600 × 1000 × 350 | 600 × 1000 × 350 |
| Shipping dimensions W × D × H (mm) | 560 × 1100 × 400 | 560 × 1100 × 400 | 560 × 1100 × 400 | 650 × 1100 × 400 | 650 × 1100 × 400 |
| Weight (kg) | 54 | 56 | 56 | 65 | 65 |
Tell us the model and the project; we will help you choose the right capacity.
After installation, this product is serviced and maintained by our group company Aktek Elektromekanik. Service by Aktek Elektromekanik

R290 heat pump for regions where winters stay around −7 °C. 12, 14 and 16 kW models, leaving water up to 55 °C.

R290 heat pump with vapour injection for long, harsh winters: 65 °C leaving water at −25 °C outdoor air, 12–16 kW.

R32 heat pump for coastal climates, with mild winters and long, hot summers. 12–16 kW heating at +2 °C outdoor air, strong cooling.